PARAMETERS |
SON-150 |
SON-250 |
SON-400 |
INPUT:
Rated Voltage |
240V
|
240V
|
240V
|
Voltage Range |
192 ~ 254 Vac |
192 ~ 254 Vac |
192 ~ 254 Vac |
Frequency |
50/60 Hz |
50/60 Hz |
50/60 Hz |
System Current |
0.64A +/- 10% |
1.04A +/- 10% |
1.67A +/- 10% |
System Circuit Power |
155W +/- 10% |
255W +/- 10% |
405W +/- 10% |
Power Factor |
> 0.98 |
> 0.98 |
> 0.98 |
Total Harmonic Distortion |
< 12% |
< 12% |
< 15% |
OUTPUT:
Lamp Type |
SON-T 150W
|
SON-T 250W
|
SON-T 400W
|
Lamp Wattage |
145W +/- 10% |
237W +/- 10% |
378W +/- 10% |
Lamp Power Factor |
> 0.98 |
> 0.98 |
> 0.98 |
Operating Frequency Range |
43 ~ 50 kHz |
48 ~ 55 kHz |
43 ~ 52 kHz |
OPERATING ENVIRONMENT
Ambient Temperature (Ta) |
0 ~ 55°C
|
0 ~ 55°C
|
0 ~ 55°C
|
Housing Temperature (Tc) |
75°C |
75°C |
75°C |
PROTECTION FEATURE:
No Load Condition |
Protection Enable,
Reset by ON/OFF
|
Protection Enable,
Reset by ON/OFF
|
Protection Enable,
Reset by ON/OFF
|
Hot Reignition Time |
Approx 1 ~ 2 min |
Approx 3 ~ 5 min |
Approx 5 ~ 10 min |
Reignition Before Tube Cooled Down |
Protection Enable,
Reset by ON/OFF |
Protection Enable,
Reset by ON/OFF |
Protection Enable,
Reset by ON/OFF |
Lamp Fault |
Protection Enable,
Reset by ON/OFF |
Protection Enable,
Reset by ON/OFF |
Protection Enable,
Reset by ON/OFF |
Inrush Current |
Suppressed |
Suppressed |
Suppressed |
MECHANICAL:
Dimensions (L) x (W) x (H) mm |
Fig. 1
|
Fig. 2
|
Fig. 3
|
Weight |
~ 650 gm |
~ 970 gm |
~ 1200 gm |
PCB |
94V0 CEM1 |
94V0 CEM1 |
94V0 CEM1 |
STANDARD DESIGN TO COMPLIED:
Safety Standard |
EN60928
|
EN60928
|
EN60928
|
Performance Standard |
EN60929 |
EN60929 |
EN60929 |
EMC Immunity |
EN61547 |
EN61547 |
EN61547 |
Current Harmonic Emission |
EN61000-3-2 |
EN61000-3-2 |
EN61000-3-2 |
Voltage Flicker |
EN61000-3-3 |
EN61000-3-3 |
EN61000-3-3 |
RFI |
EN55015/CISPR 15 |
EN55015/CISPR 15 |
EN55015/CISPR 15 |