PARAMETERS |
SON-70 |
SON-100 |
INPUT:
Rated Voltage |
240V
|
240V
|
Voltage Range |
192 ~ 254 V |
192 ~ 254 V |
Frequency |
50/60 Hz |
50/60 Hz |
System Current |
0.31A +/- 10% |
0.44A +/- 10% |
System Circuit Power |
75W +/- 10% |
106W +/- 10% |
Power Factor |
> 0.98 |
> 0.98 |
Total Harmonic Distortion |
< 12% |
< 12% |
OUTPUT:
Lamp Type |
SON-T 70W
|
SON-T 100W
|
Lamp Wattage |
68W +/- 10% |
97W +/- 10% |
Lamp Power Factor |
> 0.98 |
> 0.98 |
Operating Frequency Range |
45 ~ 52 Khz |
45 ~ 52 Khz |
OPERATING ENVIRONMENT
Ambient Temperature (Ta) |
0 ~ 55°C
|
0 ~ 55°C
|
Housing Temperature (Tc) |
75°C |
75°C |
PROTECTION FEATURE:
No Load Condition |
Protection Enable, Reset by ON/OFF
|
Protection Enable, Reset by ON/OFF
|
Hot Reignition Time |
Approx 1 ~ 2 min |
Approx 1 ~ 2 min |
Reignition Before Tube Cooled Down |
Protection Enable, Reset by ON/OFF |
Protection Enable, Reset by ON/OFF |
Lamp Fault |
Protection Enable, Reset by ON/OFF |
Protection Enable, Reset by ON/OFF |
Inrush Current |
Suppressed |
Suppressed |
MECHANICAL:
Dimensions (L) x (W) x (H) mm |
Fig. 1
|
Fig. 1
|
Weight |
~ 650 gm |
~ 650 gm |
PCB |
94V0 CEM1 |
94V0 CEM1 |
STANDARD DESIGN TO COMPLIED:
Safety Standard |
EN60928
|
EN60928
|
Performance Standard |
EN60929 |
EN60929 |
EMC Immunity |
EN61547 |
EN61547 |
Current Harmonic Emission |
EN61000-3-2 |
EN61000-3-2 |
Voltage Flicker |
EN61000-3-3 |
EN61000-3-3 |
RFI |
EN55015/CISPR 15 |
EN55015/CISPR 15 |